DOES INTER-VERTEBRAL RANGE OF MOTION INCREASE AFTER SPINAL MANIPULATION? A PROSPECTIVE COHORT STUDY
 
   

Does Inter-vertebral Range of Motion Increase
After Spinal Manipulation?
A Prospective Cohort Study

This section is compiled by Frank M. Painter, D.C.
Send all comments or additions to:
   Frankp@chiro.org
 
   

FROM:   Chiropractic & Manual Therapies 2014 (Jul 1); 22: 24 ~ FULL TEXT

  OPEN ACCESS   


Jonathan Branney, Alan C Breen

Institute of Musculoskeletal Research & Clinical Implementation,
Anglo-European College of Chiropractic,
13-15 Parkwood Road,
Bournemouth BH5 2DF, UK


Background   Spinal manipulation for nonspecific neck pain is thought to work in part by improving inter-vertebral range of motion (IV-RoM), but it is difficult to measure this or determine whether it is related to clinical outcomes.

Objectives   This study undertook to determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation, to explore relationships between any IV-RoM increases and clinical outcomes and to compare palpation with objective measurement in the detection of hypo-mobile segments.

Method   Thirty patients with nonspecific neck pain and 30 healthy controls matched for age and gender received quantitative fluoroscopy (QF) screenings to measure flexion and extension IV-RoM (C1–C6) at baseline and 4–week follow-up between September 2012–13. Patients received up to 12 neck manipulations and completed NRS, NDI and Euroqol 5D-5L at baseline, plus PGIC and satisfaction questionnaires at follow-up. IV-RoM accuracy, repeatability and hypo-mobility cut-offs were determined. Minimal detectable changes (MDC) over 4 weeks were calculated from controls. Patients and control IV-RoMs were compared at baseline as well as changes in patients over 4 weeks. Correlations between outcomes and the number of manipulations received and the agreement (Kappa) between palpated and QF-detected of hypo-mobile segments were calculated.

Results   QF had high accuracy (worst RMS error 0.5o) and repeatability (highest SEM 1.1o, lowest ICC 0.90) for IV-RoM measurement. Hypo-mobility cut offs ranged from 0.8o to 3.5o. No outcome was significantly correlated with increased IV-RoM above MDC and there was no significant difference between the number of hypo-mobile segments in patients and controls at baseline or significant increases in IV-RoMs in patients. However, there was a modest and significant correlation between the number of manipulations received and the number of levels and directions whose IV-RoM increased beyond MDC (Rho=0.39, p=0.043). There was also no agreement between palpation and QF in identifying hypo-mobile segments (Kappa 0.04–0.06).

Conclusions   This study found no differences in cervical sagittal IV-RoM between patients with non-specific neck pain and matched controls. There was a modest dose-response relationship between the number of manipulations given and number of levels increasing IV-RoM – providing evidence that neck manipulation has a mechanical effect at segmental levels. However, patient-reported outcomes were not related to this.

Keywords:   Neck pain; Manipulation; Spine kinematics; Fluoroscopy; Patient-reported outcomes



From the FULL TEXT Article:

Background

Neck pain is a common condition which most people experience at some point in their lives, with self-reported incidence rates ranging from 15.5 to 213 per 1000 person years [1] and 12–month prevalence rates around 30–50%. The condition can also be a significant cause of work absence, [2, 3] decreased productivity [4] and increased healthcare costs. [5]

Spinal manipulation, mobilisation, exercise, analgesics, acupuncture and low level laser therapy have all been shown to provide at least some degree of short-term relief of neck pain in the absence of trauma. [6] Spinal manipulation or mobilisation, particularly combined with exercise, appears to confer marginal benefit over other interventions. [7, 8] However, trials investigating manipulation for neck pain have shown conflicting results [9, 10] and while some patients respond well, others derive little benefit. One step towards understanding this would be to further our knowledge of the mechanism of action of manipulation as an intervention.

There is evidence to suggest that manipulation can decrease pain and improve function and that this is probably associated with increased motion. Nansel et al. showed that a single manipulation could reduce asymmetry of passive regional cervical spine motion, [11] while Cassidy et al. and Martinez-Segura et al. independently found that manipulation was associated with both reduced neck pain and increased regional range of neck motion immediately after treatment. [12, 13] However, regional neck range of motion is also influenced by pain, disability and fear of movement, [14] leaving the role of manipulation ambiguous. Furthermore, spinal manipulation targets specific levels, often to improve intervertebral range of motion (IV-RoM), [15] but it is not known if this actually happens, or if reduced IV-RoM is even detectable by clinical examination (palpation). To begin to explain the therapeutic effects of neck manipulation therefore requires an accurate and reproducible means of measuring maximum IV-RoM wherever it occurs in the neck bending sequence, and relating it to symptomatic changes following a course of manipulative treatment. It is also necessary to know whether reduced motion at inter-vertebral levels as detected by palpation as the basis for a manipulation can be verified.

Cineradiography and videofluoroscopy have allowed the visualisation of complete intervertebral motion sequences and have been available for many yearr, [16, 17] but analysis of the motion has been largely qualitative. However, during the last decade considerable progress has been made with detailed measurement of inter-vertebral motion using quantitative fluoroscopy (QF). [18] It is now possible to track fluoroscopic images of lumbar vertebrae continuously throughout lumbar motion in living subjects [19] allowing the measurement of true IV-RoM, regardless of where it occurs during bending. QF has been found to have good reproducibility for this, [20] but has not yet been validated or extensively used in the cervical spine. This study aimed to explore the effects of neck manipulation on IV-RoM in the cervical spine as measured by QF.

The study had four main objectives:

  1. To determine the accuracy, measurement precision and minimal detectable change (MDC) in IV-RoM over a period of treatment

  2. To determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation for non-specific neck pain and if so, the dose–response associated with such change

  3. To determine if there is any correlation between IV-RoM changes and patient reported outcomes

  4. To compare the frequency of finding inter-vertebral motion hypomobility by palpation and QF measurement.



Methods

      Study design

This was a prospective study of a cohort of patients with nonspecific neck pain receiving spinal manipulation and a matched cohort of healthy volunteers as a reference group which took place between August 2011 and April 2013. The primary outcome measure was IVRoM change after a period of manipulative treatment to the neck.

The study anticipated a number of sources of bias, such as the influence of osteoarthritic changes with age, [21] possible gender effects on neck pain disability [22, 23] and complaint duration on both clinical and biomechanical outcomes. In an attempt to minimise these, we aimed to recruit 36 participants to each group, and match them by age and gender, with an age boundary of 18–70 years and minimum complaint duration of 2 weeks. Anticipating a 20% loss to follow-up, this would provide 30 in each group. A sample size of 30 participants in each group would allow adequate opportunity for normal distributions of interval data if present [24] with a realistic recruitment target given the time and resources available. It would also give 80% power to detect a 3.5° (SD 6.5) increase in range in patients (which is the highest threshold for hypomobility, based on a review of plain film studies using the lower 2.5 percentiles of rotational range [25]) at the 95% level of significance.

      Participants

Table 1

Thirty patients who attended the Anglo-European College of Chiropractic’s (AECC) outpatient clinic for treatment of neck pain and who were suitable to receive a four-week (maximum eight sessions) course of spinal manipulation were recruited. Thirty pain-free healthy controls were recruited from staff, students and visitors to AECC and from the School of Health and Social Care a Bournemouth University. These were matched to patients for age and gender. The inclusion and exclusion criteria for patients and controls are shown in Table 1.

      Recruitment

Patients were identified by JB from first appointments at the AECC clinic for a new complaint of neck pain and were visited during their first attendance for assessment. If interested in participating, both patients and controls were assessed for eligibility using a prestudy form and were given information sheets that explained the study. If eligible and suitable for inclusion, all participants had at least 24 hours to reaffirm their decision to participate. Written informed consent was obtained from all participants and patients had all their treatments paid for from a study fund.

      Clinical assessment

Patients underwent a standard case history and examination by a final year chiropractic student intern. A further confirmatory examination was carried out by a chiropractic clinical tutor at which confirmation of suitability for a course of neck manipulation was sought and palpation findings for inter-vertebral motion were recorded. Informed consent, followed by the start of main data collection began prior to treatment, which commenced at the second visit. This included assessment for a history of diagnosed depression in the previous year and pressure algometry (Somedic Ltd, Sweden) for the assessment for pain central sensitisation. Ethical approval was granted by the UK National Research Ethics Service South West – Cornwall and Plymouth (11/SW/0072).

      Data collection

Figure 1

The study proceeded according to the flow diagram in Figure 1. Before any treatment commenced, participants received QF screenings of cervical flexion and extension motion (separately) under a standardised protocol (described below). All screenings were conducted in the mid-mornings to avoid diurnal effects.

Patients completed an 11–point numerical rating scale for pain (NRS), the Neck Disability Index (NDI), [26] and the EuroQol EQ-5 L. [27] These, plus the Patient Global Impression of Change (PGiC) [28, 29] were completed again at 4 weeks along with a single satisfaction question. [30] The number of treatment visits, specific levels manipulated and their frequency were recorded for each patient. At 4 weeks, a second set of identical QF screenings were performed for all participants. Adverse events were recorded.

      Image sequence recording and analysis

Figure 2

The QF equipment consisted of a Siemens Arcadis Avantic VC10A digital fluoroscope (CE 0123, Siemens, Germany) and a vertical motion frame (Atlas Clinical Ltd. UK) with remote controller (Daqfactory Ltd. UK), stool and protective lead gonad shielding (Figure 2). After demonstration of the procedure, patients sat with their right shoulder next to the motion frame in a position that was judged ‘neutral’ to the operator using the infraorbitalmeatal line as a reference. This position was then fixed with sternal and thoracic (T5) bracing rods.

Participants completed a warm-up of 5 flexion-extension repetitions to reduce range variability [31] followed by recording of their maximum comfortable flexion and extension ranges using the CROM instrument (Performance Attainment Associates Inc. USA). A face rest rigidly attached by an extendable rod to the rotating disc section of the motion frame was brought to touch the patient’s cheeks with instructions to follow it during fluoroscopy, which was carried out with the central ray located in the C3–4 disc. The motion frame controller was set to reproduce the participants’ maximum attainable flexion and extension ranges after warm-up. This was synchronised with the QF screening procedure which recorded fluoroscopy sequences at 15frames per second during the motion. Recordings of measurements of the equipment positioning were made for duplication at follow-up. Radiation exposure data were recorded with a dose area product meter and effective dosage calculated using Monte Carlo simulation software (PCXMC) using the latest tissue weighting factors. [32]

Figure 3

Following screening, the image files (DICOM) were exported for analysis using bespoke image tracking and analysis codes written in Matlab (The Mathworks Ltd. UK) and accessed through a graphic user interface. The operator drew lines around the cortical margins of each vertebra from C1–C6 with the screen cursor to form tracking templates. These were linked to reference templates derived from 4–point vertebral body corner co-ordinates. This generated positional information for each vertebra and automatically calculated inter-vertebral rotations using a method similar to that used in the lumbar spine. [18] The output gave maximum IVRoM data for each level and direction regardless of whether this occurred at the end of global range or not (Figure 3).

      Accuracy and repeatability of IV-RoM measurement

The accuracy of IV-RoM measurement using QF from continuous motion was determined using a model made from dry human C4–5 vertebrae joined at the vertebral body centres by a unidirectional plastic joint. This was mounted on a testing platform on the vertical motion frame and a digital inclinometer (Penny & Giles STT280; resolution +/–0.07°) was mounted on the superior vertebra to record tilting motion. The model was rotated by attaching its movable superior vertebra to a beam which was in turn rigidly attached to the rotating disc on the motion frame. This moved separately through 20° of flexion and 20° of extension at the same velocity as used for patient examinations. A block of minced beef was interposed between the X-ray source and the model to simulate soft tissue degradation. This test was repeated with the model rotated axially through 10° to invoke poor positioning. Maximum IV-RoM was measured 10 times by one observer for each range and orientation. Results were expressed as root-mean-square (RMS) differences between reference and index measurements.

Intra- and inter-observer repeatability was determined for inter-vertebral levels C1–6 in the first 10 participants recruited. Two trained observers (JB and a chiropractic student) independently analysed all 10 participants for maximum IV-RoM using the standard operating procedure for image analysis in the inter-observer study. JB then repeated the analysis of the same sequences 6 weeks later to determine intra-observer variation. Agreement was calculated for both tests as standard errors of measurement (SEM) [33] and intraclass correlation coefficients (ICC 2C,1 and 3C,1) for reliability. [34]

      Interventions

Permitted treatments were given a maximum of twice a week for 4 weeks. These consisted of high velocity, low amplitude (HVLA) manipulation of the cervical spine using diversified techniques. [15] Myofascial trigger point therapy and/or light massage, hot/cold packs and analgesics were allowed if required. These are considered typical approaches for neck pain. [35] Mobilisation, passive or active muscle stretching and rehabilitation exercises were not allowed. Manipulation was carried out by qualified chiropractors with at least 5 years of practice experience.

      Data analysis

Table 2

Age, gender and prevalence of radiographic anomalies were determined for both cohorts from baseline information, along with IV-RoM. At baseline, the latter was determined for all inter-vertebral levels in both directions from C1–6 in patients and controls and compared. Thresholds for designating motion at each level as ‘hypomobile’ were generated from four well-documented plain X-ray studies [25, 36–39], and summarised by Dietz et al. [25] Table 2.

The minimal detectable change (MDC) in IV-RoM that could be expected due to measurement error in the absence of any intervention was calculated from control data as 2.77xSD of its intra-subject difference over 4 weeks. [40] IV-RoM changes beyond MDC for each level and direction were then calculated in patients. Correlations between the number of manipulations received by patients and the number of levels from C1–6 that increased beyond MDC were performed. Finally, correlations between IV-RoM changes beyond MDC in patients and NRS, NDI, EQ-5D changes, PGIC and satisfaction scores were determined.

All interval data were inspected for normality and statistical analyses were performed accordingly using SPSS (V21, IBM Software Ltd.) Differences in patients and controls were determined by unpaired t-tests, and between baseline and follow-up in patients by Wilcoxon Signed-Rank tests. Correlations between change scores and range increases were analysed using the Spearman correlation coefficient. Analysis of proportions of dichotomous variables was by 2–way Fisher Exact tests for comparison of cohorts and by Cohen’s Kappa statistic [41] for agreement between palpated and measured hypo-mobility. The cut-off for statistical significance was set at 0.05.



Results

Of 191 patients approached, 30 were eligible and agreed to participate. Of these, 30 patients and 30 controls provided full documentation and imaging data. One patient’s imaging analysis failed and could not be recovered, therefore 29 patients and 30 healthy controls were analysed. Patients received a mean of 1.3 neck manipulations per visit (SD 0.4) and 10.7 over the course of the study (SD 3.5). The number of patients who received additional treatments was: trigger point therapy (27), light massage (27), hot or cold pack (7) and over the counter medication (18). Average radiation dose was (0.013 mSv), representing an additional cancer risk of 1:1 million. [42]

      Accuracy and repeatability for range of motion, MDC and hypo-mobility cutoffs

Accuracy was high for IV-RoM (worst RMS error 0.5°) as was intra and inter-observer repeatability (highest SEM 1.1°, lowest ICC 0.90), Hypo-mobility cut offs ranged from 0.8° to 3.5° (Table 2).

The MDCs for flexion and extension IV-RoM over 4 weeks ranged from 3.0° (flexion at C2–3) to 6.4° (extension at C3–4). The MDC over the 4 week intervention period represents the smallest change that could not be attributed to normal variation and/or measurement error for these levels.

      Subject characteristics

Table 3

The baseline characteristics of the participants are shown in Table 3. The average age of participants was 40 years (SD 13.1). Seventy percent were female, with no significant differences between patients and controls. In patients, the median duration of symptoms was 12 months (interquartile range 2–36) and 17/29 had pain at other sites. The mean baseline severity for pain and disability were NRS 5/10 and NDI 13/50 respectively. None had pain pressure thresholds below the reference norms. [43]

      Hypo-mobility

Figure 4

Table 4

Table 5

The baseline IV-RoMs in patients and controls are shown in Figure 4. Patients had on average less inter-vertebral motion in extension at levels between C1–6 (mean 5.7°) and less in flexion (mean 1.5°) at baseline than controls, but none were statistically significant (p > 0.05). There was also no significant difference between the number of hypo-mobile levels detected at baseline and follow-up in patients. Hypo-mobility was detected on measurement less frequently than on palpation and there was little agreement between examiner recognition of hypo-mobile segments and the frequency of being measured below hypomobiity thresholds, even when adjacent levels were included (Table 4).

      Patient outcomes

A summary of patient outcomes is given in Table 5. Eighty-seven percent of patients had at least a 30% improvement, as reflected in PGiC scores, at the end of the treatment period. However, there was no relationship between any of the patient-reported outcomes and changes in IV-RoM beyond MDC at any level (Table 5). No serious adverse events occurred. However, temporary increases in symptoms were recorded at some point in the treatment period in 19/29 patients and headaches following treatment were recorded in 2/29. Most of these resolved within 24 hours and all were resolved by 96 hours. Two patients received treatments outwith the study protocol, consisting of manipulation to the thoracic spine at two treatment visits. One patient received cervical spine traction and muscle stretching techniques at one treatment visit.

      Dose response

Figure 5

There was a modest, but significant positive correlation between the number of manipulations received and the number of levels that increased in range at 4 weeks beyond their MDCs (Rho = 0.39, p = 0.043) (Figure 5). Furthermore, a significantly higher proportion of levels increased their IV-RoM in patients (13/16) who had at least 4 manipulations than at the same levels in controls (2/23, 2–sided p = 0.002 – Fisher exact). Most of these levels were not, however hypo-mobile at baseline. Of the patient levels that were hypo-mobile at baseline, only one increased its range by more than the MDC after treatment.

      Main result

Of importance is the finding that sagittal plane hypomobile segments were not significantly more prevalent in patients than in controls, casting doubt on the relevance of sagittal plane hypomobility in patients with relatively mild non-specific neck pain. However, this may not be the case in other populations and planes of motion. Indeed, such hypomobility may be of importance only in a subgroup of neck patients.

The lack of a relationship between symptomatic improvement and increased IV-RoM is also of interest. Clearly other mechanisms that improved the comfort and functional capacity of the patients in this study were in play, including spontaneous recovery. Other important biological factors may have included chemical factors in joint and muscle and activation patterns in the latter. However, this study seemed to rule out central pain hypersensitivity as a factor, as this was not detected at baseline in any of the patients. Psychological and social factors and their influence on functional behavior may also have had a role and may have been influenced by the interventions received.

Finally, it is of interest that there was a significant correlation (Rho = 0.39), albeit modest, between the number of manipulations received and the number of inter-vertebral levels that increased their IV-RoMs beyond MDC. Given the magnitude of some MDCs, it seems unlikely that this was a chance finding.

      Context of findings

There has been a growing body of research into motion-related dysfunction of the cervical spine. Many investigators have concluded that abnormal cervical spine kinematics, measured non-invasively, provides important diagnostic information in the evaluation of patients with neck disorders. Reduced range of regional motion, slow movement, repositioning errors, reduced coordination of movement, and lower peak velocities have all been demonstrated in chronic neck pain patients compared to controls. [44–47] Vogt et al. found that maximal cervical ROM was significantly lower, and movement variability significantly higher in chronic neck pain patients compared to healthy age-matched controls. [48]

While some of these studies have identified what appear to be important motion differences in patients with spinal pain, the measurement methods used reflect regional motion, and do not reveal what is actually happening inside the neck [49] – or provide evidence about the extent to which differences are biomechanical or behavioural. The present study found little difference between patients and controls in terms of IV-RoM at baseline when participants were asked to reach their maximum range. Nevertheless, as with previous studies, patients had significantly lower voluntary regional motion ranges than controls at baseline (Table 3), which suggests that a behavioural element may be in play. However, it is difficult to imagine how the apparent dose–response effect at inter-vertebral levels in patients following manipulation could be anything other than mechanical when regional motion was set to the same range at follow-up as at baseline. This research therefore provides the first evidence suggestive of mechanical effects of treatment by manipulation at the inter-vertebral level. However, these changes were not related to patient reported outcomes.


Limitations

QF was found to have high accuracy and repeatability for measuring sagittal plane IV-RoM in the cervical spine. However, high intra-subject variation across time at some levels (e.g. C3–4 in extension) will limit the ability of the present method, however accurate and precise, to measure changes in sagittal IV-ROM at some levels. Further refinement of the motion control protocol during image acquisition is therefore needed.

Our analysis only reports IV-ROM, and only in the sagittal plane. However, other kinematic parameters, such as translation, instantaneous axis of rotation and attainment rate (laxity) are also measurable with this method and some may be more responsive to change. Other planes of motion are also of interest, but are problematical for X-ray imaging due, for example, to the superimposition of the mandible and tracheal air space in the anterior-posterior projection and the lack of accessibility of axial or coupled motion with these methods. Palpation of the cervical spine for hypomobility is also typically carried out in all these directions, plus the oblique plane, thus providing a possible explanation for their more frequent detection by palpation and indicating the need for a 3-D method if this study is to be improved upon.



Conclusion

This study found no differences in cervical sagittal IV-RoM between patients with mild nonspecific neck pain and matched healthy controls and motion palpation over-estimated the prevalence of hypomobile segments. There was, however, a modest positive relationship between the number of spinal manipulations given and detectable increases in sagittal segmental IV-RoM. The patient-reported outcomes of spinal manipulation were not related to this, nor was there any relationship between increase in range and improvement in pain and disability, even though these improvements were generally large.


Competing interests

The authors declare they have no competing interests.


Authors’ contributions

This article is based on the PhD Thesis of JB, based on a concept generated by AB. All data were collected by JB assisted in part by AB. JB conducted all the analysis. Both authors contributed to the paper. Both authors read and approved the final manuscript.


Acknowledgements

Funding for this study was provided by the EAC European Chiropractors Union Research Fund and the AECC Treatment-a-Month Club. We gratefully acknowledge the help of Alex Breen with software support, Suzanne Jasperse for measuring and analyzing IV-RoM for the inter-observer study and Gert Bronfort, Jenni Bolton and Sarah Hean for their advice in the course of this work. Written informed consent was obtained for all images of participants. Finally, a debt is owed to all the chiropractors and interns who carried out and recorded assessments and administered treatments and to the staff and students who volunteered to participate.



References:

  1. Hogg-Johnson, S, van der Velde, G, Carroll, LJ et al.
    The Burden and Determinants of Neck Pain in the General Population: Results of the
    Bone and Joint Decade 2000–2010 Task Force on Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S39–51

  2. Cote PD, Kristman V, Vidmar M, Van Eerd D, Hogg-Johnson S, Beaton D, Smith PM:
    The prevalence and incidence of work absenteeism involving neck pain: a cohort of Ontario lost-time claimants.
    Spine 2008, 33(4S):S192–S198. Neck Pain Task Force (Supplement).

  3. HSE:
    Self-reported work-related illness and workplace injuries in 2008/2009:
    Results from the Labour Force Survey.
    In Health and Safety Executive. 2009

  4. Dagenais S, Haldeman S:
    Commentary: laboring to understand the economic impact of spinal disorders.
    Spine J 2012, 12:1119–1121

  5. Borghouts JAJ, Koes BW, Vondeling H, Bouter LM:
    Cost-of-illness of neck pain in The Netherlands in 1996.
    Pain 1999, 80:629–636

  6. Guzman J, Haldeman S, Carroll LJ, et al.
    Clinical Practice Implications of the Bone and Joint Decade 2000-2010
    Task Force on Neck Pain and Its Associated Disorders:
    From Concepts and Findings to Recommendations

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S199–S212

  7. Hurwitz, EL, Carragee, EJ, van der Velde, G et al.
    Treatment of Neck Pain: Noninvasive Interventions: Results of the Bone and Joint Decade
    2000–2010 Task Force on Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S123–152

  8. Miller J, Gross A, D'Sylva J, et al.
    Manual Therapy and Exercise for Neck Pain: A Systematic Review
    Man Ther. 2010 (Aug); 15 (4): 334–354

  9. Bronfort G, Evans R, Anderson AV, Svendsen KH, Bracha Y, Grimm RH.
    Spinal Manipulation, Medication, or Home Exercise With Advice for Acute and Subacute Neck Pain:
    A Randomized Trial

    Annals of Internal Medicine 2012 (Jan 3); 156 (1 Pt 1): 1–10

  10. Evans R, Bronfort G, Schulz C, Maiers M, Bracha Y, Svendsen K,
    Grimm R Jr, Garvey T, Transfeldt E:
    Supervised Exercise With And Without Spinal Manipulation Performs
    Similarly And Better Than Home Exercise For Chronic Neck Pain:
    A Randomized Controlled Trial

    Spine (Phila Pa 1976). 2012 (May 15);   37 (11):   903–914

  11. Nansel D, Cremata E, Carlson J, Szlazak M:
    Effect of unilateral spinal adjustments on goniometrically-assessed cervical lateral-flexion end-range asymmetries in otherwise asymptomatic subjects.
    J Manip Physiol Ther 1989, 12(6):419–427.

  12. Cassidy JD, Quon JA, Lafrance LJ, Yong-Ling K:
    The effect of manipulation on pain and range of motion in the cervical spine: pilot study.
    J Manip Physiol Ther 1992, 15(8):495–500

  13. Martinez-Segura R, Fernandez-de-las-Penas C, Ruiz-Saez M.
    Immediate Effects on Neck Pain and Active Range of Motion After a Single
    Cervical High-velocity Low-amplitude Manipulation in Subjects Presenting
    with Mechanical Neck Pain: A Randomized Controlled Trial

    J Manipulative Physiol Ther 2006 (Sep); 29 (7): 511–517

  14. Bahat HS, Weiss PL, Sprecher OTE, Krasovsky A, Laufer PTY:
    Do neck kinematics correlate with pain intensity, neck disability or with fear of motion?
    Man Ther 2014, 19(3):252–258

  15. Peterson DH, Bergmann TF:
    Chiropractic technique: principles and procedures. 2nd edition.
    Mosby Inc: St Louis, Missouri; 2002.

  16. Fielding JW:
    Cineradiography of the normal cervical spine.
    N Y State J Med 1956, 56(19):2984–2986

  17. Woesner ME, Mitts MG:
    The evaluation of cervical spine motion below C2: a comparison of cineroentgenographic and conventional roentgenographic methods.
    Ann Phys Med 1972, 115(1):148–154

  18. Breen AC, Teyhan DS, Mellor FE, Breen AC, Wong KWN, Deitz A:
    Measurement of InterVertebral motion using quantitative fluoroscopy: report of an international forum and proposal for use in the assessment of degenerative disc disease in the lumbar spine.
    Adv Orthop 2012, 2012: Article ID 802350

  19. Mellor F, Muggleton JM, Bagust J, Mason W, Thomas PW, Breen AC:
    Mid-lumbar lateral flexion stability measured in healthy volunteers by in-vivo fluoroscopy.
    Spine 2009, 34(22):E811–E817

  20. Mellor FE, Thomas P, Thompson P, Breen AC:
    Proportional lumbar spine intervertebral motion patterns: a comparison of patients with chronic, non-specific low back pain and healthy controls.
    Eur Spine J 2014. DOI: 10.1007/s00586-014-3273-3

  21. Simpson A, Biswas D, Emerson JW, Lawrence BD, Grauer JN:
    Quantifying the effects of age, gender, degeneration, and adjacent level degeneration on cervical spine range of motion using multivariate analyses.
    Spine 2008, 33(2):183–186

  22. Cote P, Cassidy JD, Carroll LJ, Kristman V:
    The annual incidence and course of neck pain in the general population: a population-based cohort study.
    Pain 2004, 112:267–273

  23. Tilscher H, Pirker-Binder I, Kollegger M, Pfeiffer F:
    Head, neck, shoulder, arm: workplace related? an increasing problem for women (in German “Kpf-nackenschulter-arm-beschwerden: arbeitsplatzbedingt?”.
    Man Med 2005, 43:13–18

  24. Field A:
    Discovering Statistics Using SPSS. 3rd edition.
    London: Sage; 2009.

  25. Deitz AK, Breen AC, Mellor FE, Teyhan DS, Panjabi MM, Wong KWM:
    Kinematics of the aging spine: a review of past knowledge and survery of recent developments, with a focus on patient-management implications for the clinical practitioner.
    In The Comprehensive Treatment of the Aging Spine: Minimally Invasive and Advanced Techniques.
    Edited by Yue G, Johnson JP, Khoo LT, Hochschuler SH.
    Philadelphia: Saunders; 2011:51–62

  26. Vernon HT, Mior S:
    The Neck Disability Index: A Study of Reliability and Validity
    J Manipulative Physiol Ther 1991 (Sep); 14 (7): 409–415

  27. Herdman M, Gudex C, Lloyd A, Janssen M, Kind P, Parkin D, Bonsel G, Badia X:
    Development and preliminary testing of the new five-level version of EQ-5D (EQ-5D-5L).
    Qual Life Res 2011, 20(10):1727–1736

  28. Farrar JT, Young JP, Jr, LaMoreaux L, Werth JL, Poole MR.
    Clinical Importance of Changes in Chronic Pain Intensity
    Measured on an 11-point Numerical Pain Rating Scale

    Pain 2001 (Nov); 94 (2): 149-158

  29. Bolton JE:
    Sensitivity And Specificity Of Outcome Measures In Patients With Neck Pain:
    Detecting Clinically Significant Improvement

    Spine (Phila Pa 1976). 2004 (Nov 1);   29 (21):   2410-2417

  30. Hudak P, Wright JG:
    The characteristics of patient satisfaction measures.
    Spine 2000, 25(24):3167–3177

  31. Tousignant M, Boucher N, Bourbonnais J, Gravelle T, Quesnel M, Brosseau L:
    Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects.
    Man Ther 2001, 6(4):235–241

  32. ICRP: Title page.
    Ann ICRP 2007, 37(2–4):i-i

  33. de Vet HCW, Terwee CB, Knol DL, Bouter LM:
    When to use agreement versus reliability measures.
    J Clin Epidemiol 2006, 59(10):1033–1039

  34. Shrout PE, Fleiss JL:
    Intraclass correlations: uses in assessing rater reliability.
    Psychol Bull 1979, 86(2):420–428

  35. Leaver AM, Refshauge KM, Maher CG, McAuley JH:
    Conservative interventions provide short-term relief for non-specific neck pain: a systematic review.
    J Physiother 2010, 56(2):73–85

  36. Dvorak J, Froehlich D, Penning L, Baumgartner H, Panjabi MM:
    Functional radiographic diagnosis of the cervical spine: flexion/extension.
    Spine 1988, 13:748–755

  37. Aho A, Vartianinen O, Salo O:
    Segmentary antero-posterior mobility of the cervical spine.
    Ann Med Intern Fenn 1955, 44:287–299

  38. Frobin W, Leivseth G, Biggemann M, Brinckmann P:
    Sagittal plane segmental motion of the cervical spine: a new precision measurement protocol and normal motion data of healthy adults.
    Clin Biomech 2002, 17:21–31

  39. Lind B, Sihlbom H, Nordwall A, Malchau H:
    Normal range of motion of the cervical spine.
    Arch Phys Med Rehabil 1989, 70:692–695

  40. Bland JM, Altman DG:
    Statistics notes: measurement error.
    BMJ 1996, 313(744)

  41. Cohen J:
    A coefficient of agreement for nominal scales.
    Educ Psychol Meas 1960, 20(1):37–46

  42. Hart D, Wall BF, Hillier MC, Shrimpton PC:
    Frequency and Collective Dose for Medical and Dental X-ray Examinations in the UK, 2008.
    Oxford: Health Protection Agency; 2010

  43. Neziri AY, Scaramozzino P, Andersen OK, Dickenson AH, Arendt-Nielsen L, Curatolo M:
    Reference values of mechanical and thermal pain tests in a pain-free population.
    Eur J Pain 2011, 15(4):376–383

  44. Antonaci F, Bulgheroni M, Ghirmai S, Lanfranchi S, Dalla Toffola E, Sandrini G, Nappi G:
    3D kinematic analysis and clinical evaluation of neck movements in patients with whiplash injury.
    Cephalalgia 2002, 22:533–542

  45. Feipel V, Rondelet B, LePallec JP, DeWitte O, Rooze M:
    The use of disharmonic motion curves in problems of the cervical spine.
    Int Orthop 1999, 23:205–209

  46. Ohberg F, Grip H, Wiklund U, Sterner Y, Karlsson JS, Gerdle B:
    Chronic whiplash associated disorders and neck movement measurements: an instantaneous helical axis approach.
    IEEE Trans Inf Technol Biomed 2003, 7(4):274–282

  47. Sjolander P, Michaelson P, Jaric S, Djupsjobacka M:
    Sensorimotor disturbances in chronic neck pain - range of motion, peak velocity, smoothness of movement, and repositioning acuity.
    Man Ther 2008, 13:122–131

  48. Vogt L, Segieth C, Banzer W, Himmelreich H:
    Movement behaviour in patients with chronic neck pain. Physiother Res Int 2007, 12(4):206–212

  49. Bogduk N, Mercer S:
    Biomechanics of the cervical spine, I: normal kinematics.
    Clin Biomech 2000, 15:633–648

Return to RADIOLOGY

Return to CHIROPRACTIC ADJUSTING

Since 7-04-2014

© 1995–2025 ~ The Chiropractic Resource Organization ~ All Rights Reserved